Siemens is assessing the impact of CVE-2026-111497 on its Industrial Edge Management (IEM) products, according to a Siemens ProductCERT advisory (SSA-443410) republished by CISA on 2026-11-12.
The vulnerability is a buffer overflow in the Brotli decoder in Google Brotli versions 1.0.3 through 1.2.0. The advisory says a remote, unauthenticated attacker could use a crafted Brotli-compressed stream to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code. Siemens rates it 9.8 (Critical) under CVSS v3.1. The weakness is classified as CWE-787, Out-of-bounds Write. Users should update Brotli libraries to 1.0.10, 1.1.1, or 1.2.1.
Siemens says the affected Brotli library is included in the IEM software stack. It states that no action is required if no Management Applications are installed, because the affected functionality is not used or exposed. Where Management Applications or Device Applications are installed, Siemens advises following specific mitigations until fixes are available.
Fix status varies by product